ELISA
Enzyme-linked immunosorbent assay (ELISA) is an immunoassay based on antigen–antibody specificity coupled with enzyme-colorimetric reaction for qualitative/quantitative detection. Established in 1971 by Engvall and Perlmann from RIA/EIA, it is now a core biomedical method. ELISA overcomes low sensitivity, complexity, and inability to batch-test of older methods, offering high specificity, sensitivity, simplicity, low cost, stability, and automation for quantifying proteins, hormones, and pathogen antigens/antibodies. It spans medical diagnostics (infectious disease, tumor markers, autoimmunity), food safety (pathogens, toxins), and research (cytokines, protein levels), fitting both clinical small samples and large seroepidemiological screens.

Principle Introduction
ELISA immobilizes antigen or antibody on a solid phase (polystyrene plate); antigen–antibody binding forms an immune complex, and enzyme-labeled antibody converts colorless substrate to colored product whose absorbance (OD) quantifies the target, in 4 steps: coat capture antigen/antibody; block non-specific sites with milk/BSA; add sample and enzyme-labeled antibody to form the plate-capture-target-enzyme complex; add substrate (e.g., TMB for HRP), stop, and read OD—color intensity correlates with concentration.
Literature
Microbiology Spectrum published "Remapping the spatial distribution of neutralizing sites and their immunodominance on the capsid of different topotypes of FMDV serotype O by site-directed competitive ELISA for detection of neutralizing antibodies." Addressing unclear O-type FMDV epitopes, 27 neutralizing antibodies in paired competitive ELISA split capsid neutralizing sites into 6 regions, finding two novel ones. Sera from cattle, sheep, and pigs vaccinated with four lineages were analyzed by site-directed competitive ELISA. Neutralizing-antibody titers against site 6 correlated strongly with virus-neutralization results (r=0.8693), systematically mapping O-FMDV neutralizing sites and locking a key surrogate marker for high-throughput neutralizing-antibody assays.
Sample Requirements
>200μL/sample, no hemolysis/lipemia, -20℃, dry ice, no freeze–thaw.
>500μL/sample, 4℃ spin to remove debris, -20℃, dry ice.
>0.5g/sample, snap-frozen -80℃, dry ice; provide homogenization buffer.
≥1mg/mL, ≥500μL, purity >85%, -80℃, dry ice; provide activity report.
lyophilized or solution (≥10μg/mL), -20℃ dark, cold pack; provide concentration and source.
Deliverables
Raw data
plate reader OD records, well images, standard-curve fit and equation.
Quantification report
target concentration with SD, CV, positive/negative call, comparison to standard.
Full report
principle, instruments/reagents, procedures, QC records, discussion.
Technical documentation
method optimization, storage, troubleshooting.
FAQ
① insufficient blocking (milk→BSA, longer); ② incomplete washing; ③ high enzyme-antibody concentration; ④ over-long substrate incubation.
① below detection (concentrate/lower dilution); ② short incubation; ③ lost coating activity; ④ expired substrate/antibody.
① uneven pipetting (calibrate); ② uneven well temperature (water bath); ③ unmixed reagents; ④ bubbles—tap out before reading.